BAABS rotates around the blast hose during operation. As it rotates, the power cable can gradually twist and tighten around the hose. Over time, this tension may cause the electrical connections to loosen or disconnect.
To prevent this from happening, periodically relieve the tension in the cable by performing one of the following steps when the blast pot is shut off:
• Unplug the power cord and unwind the cable.
• Remove the G3 Trigger Deadman and unwind the cable.
• Reverse the BAABS rotation to unwind and loosen the cable.
Regularly relieving cable tension will help maintain proper cable condition and prevent electrical connection issues.