Frequently Asked Questions

Have you seen any ‘aha moments’ where a simple fix made a huge difference?

Simply replacing a worn nozzle with a new properly sized nozzle. We have seen blasters using a #8 nozzle but using them so far past the nozzle’s life expectancy to where they are 1” in diameter. Vessels will not function properly with an improperly sized nozzle because the compressor can’t maintain the proper pressure. Your metering becomes inaccurate. When you pull that much air across an air dryer or air receiver this equipment will not have enough time to dry the air.